ZETLAN TECHNOLOGIES
Course Categories 172+
Cloud & Infrastructure 7
Networking 8
Virtualisation 5
IT Security 10
CyberSecurity & Mgmt 14
Software Development 16
Web Dev & Database 27
Data Science & AI 14
Mobile, Testing & Games 22
Design & Creative 49
Navigation
Home Business About Us Contact Us All Courses FAQ & Help
Contact Us
+91 8680961847 +91 8680961847 (WhatsApp) info@zetlantechnologies.com
Browse by Domain
Cloud & Infrastructure 7
Networking 8
Virtualisation 5
IT Security 10
CyberSecurity & Mgmt 14
Software Development 16
Web Dev & Database 27
Data Science & AI 14
Mobile, Testing & Games 22
Design & Creative 49
2000+ Courses · 15+ Technology Domains
Microsoft Cisco AWS EC-Council View All Courses
D-XTR-DY-A-24
/ Dell Certifications / D-XTR-DY-A-24
Dell Proven Professional · Deploy · D-XTR-DY-A-24

Dell XtremIO

Deploy

Master XtremIO X2 deployment — hardware fundamentals, physical installation, initial cluster configuration, and day-to-day management for all-flash enterprise storage environments.

XtremIO X2 Hardware Rack & Cable iDRAC Configuration XMS Deployment Cluster Init Volume Provisioning FC Zoning iSCSI iGroups SolVe Online ESRS Remote MPIO/PowerPath XMS REST API
Enroll Now Brochure
D-XTR-DY-A-24 — XtremIO X2 Deploy Architecture
XtremIO Deploy — D-XTR-DY-A-24 Four-Phase Flow HW Fundamentals Installation Initial Config Management X-Brick: Controllers+SSDs InfiniBand IB switch BBU / SuperCap NVRAM DAE drives + enclosures iDRAC management NIC Rack/cable DAE & X-Brick iDRAC IP + FW verify JBOD cable verify in XMS Power-on IB→DAE→Ctrl SolVe Online guided steps XMS deploy (OVF/physical) Create XtremIO cluster IB switch + subnet mgr FC zoning + iGroup create Map volumes to hosts XMS GUI dashboards xcli + REST API scripts Snapshot & clone ops ESRS call-home setup XCU rolling upgrade Infrastructure Layer PowerEdge controllers · XtremIO IB switch · Management LAN · SAN fabric (FC / iSCSI) · iDRAC OOB Host Protocol Deployment FC: HBA zoning + WWN · iSCSI: IP, CHAP, iGroups · ESXi VAAI/VASA plugin · MPIO/PowerPath/DM-Multipath Inline Data Services Deduplication (global CAS inline) Inline compression (no latency hit) Encryption at rest (D@RE) Thin provisioning + UNMAP reclaim Management & Support XMS: GUI, CLI, REST API ops ESRS remote support + call-home SolVe Online HW procedures Performance dashboards + alerting D-XTR-DY-A-24 — Dell Proven Professional Deploy Certification Module Coverage HW Fundamentals Installation Initial Config Management
4
Modules
Full D-XTR-DY-A-24 scope
20+ hrs
Duration
Lab-intensive deploy
Deploy
Level
Hands-on install
24/7
Support
Expert guidance
Exam At a Glance
🧪
D-XTR-DY-A-24
Exam Code
XtremIO Deploy
🌐
English
Language
English only
🔧
Deploy
Level
Deployment level
🏅
Dell Proven
Credential
Professional cert
🔄
2 Years
Validity
Recertify required
None
Pre-req
No formal prerequisites
What You Will Learn

Four XtremIO Deploy Modules

From hardware fundamentals through physical installation, initial cluster configuration, and production management — end-to-end XtremIO X2 deployment expertise.

Module 01
XtremIO Hardware Fundamentals
  • XtremIO X2 hardware: Storage Controllers (X-Brick), InfiniBand switch, Drive Array Enclosures (DAE), BBU/SuperCap-protected NVRAM; architecture for sub-1ms latency guarantee
  • X-Brick architecture — dual redundant controllers per X-Brick; NVRAM write-buffer; XDP cross-cluster erasure coding; scaling performance by adding X-Bricks
  • XtremIO vs X2 differences — NVMe SSDs, higher per-X-Brick density, upgraded NVRAM; X2 performance improvements for VDI and database workloads
  • InfiniBand fabric — IB switch role in multi-X-Brick communication; RDMA transfers; subnet manager; IB cable and firmware requirements
  • DAE enclosure components — SAS/NVMe drives, enclosure management module (EMM), hot-swap procedures, DAE capacity expansion
  • XMS management hardware — XMS as physical appliance or virtual appliance; management network topology; iDRAC/BMC out-of-band access
Module 02
XtremIO X2 Installation
  • Rack and cable XtremIO X2 — 42U rack requirements, X-Brick placement, IB cabling, DAE SAS/NVMe cabling, management LAN, dual-PDU power redundancy
  • SolVe Online guided procedures — step-by-step FRU/install guide; procedure selection for hardware models; offline export for air-gapped environments
  • iDRAC initial setup — network config (IP/subnet/GW); firmware verification; remote KVM for headless install; iDRAC license requirements
  • JBOD/DAE cable verification — verify SAS/NVMe connections using XMS disk view; enclosure connectivity status; re-seat/replace cables on mis-detected drives
  • Power-on sequence — proper order: IB switch first, then DAEs, then Controllers; verify healthy IB link state; wait for XMS discovery; initial health check
  • Physical tooling and safety — site survey checklist; cable management; required tools; floor tile removal; labeling conventions for data center installs
Module 03
XtremIO X2 Initial Configuration
  • XMS deployment — OVF deploy for VM, or physical XMS setup; network configuration; initial web UI access; XMS to X-Brick discovery
  • Cluster creation — add X-Bricks; set cluster name, NTP time, management IPs; cluster initialization workflow; verify cluster health in XMS dashboard
  • IB switch configuration — initial IP; firmware update procedure; IB subnet manager (SM) config; verify IB fabric topology; troubleshoot IB link errors
  • FC zoning and iGroup setup — WWN discovery; SAN switch zoning for XtremIO controllers; iGroups in XMS (FC or iSCSI); host initiator registration
  • Volume creation and mapping — create volumes (name, size, thin-provisioned); map to iGroups; volume tags; snapshot sets for consistency groups; host SCSI discovery
  • Post-deployment validation — XMS health check; all X-Bricks healthy; NVRAM BBU/SuperCap status; multipath (PowerPath/DM-Multipath) verification; IB bandwidth metrics
Module 04
XtremIO X2 Management
  • XMS GUI daily operations — dashboards: capacity, performance (IOPS/bandwidth/latency), health; event log review; email/SNMP alerts; user account management
  • XMS CLI and REST API — xcli syntax for scripting; REST API endpoint discovery; automated snapshot scheduling; integration with monitoring platforms
  • Snapshot and clone operations — CG snapshot sets for consistency; snapshot refresh for dev/test; writeable snapshots; snapshot delete and space reclamation
  • Performance monitoring and tuning — per-volume and per-host counters; hot volume identification; per-volume throttling; FIO/IOmeter benchmarking
  • ESRS remote support — configuring ESRS call-home for XtremIO; auto case creation for HW alerts; testing ESRS connectivity; SRS Gateway configuration
  • Upgrade and lifecycle management — rolling XCU upgrade via XMS; X-Brick FW updates; IB switch FW; verify upgrade success in XMS; upgrade without downtime
Technologies You Will Master
XtremIO X2
XMS Management
X-Brick Deploy
IB Switch
SolVe Online
iDRAC Setup
FC Zoning
iSCSI iGroups
NVRAM BBU
DAE Cabling
ESRS Remote
xcli Scripts
Snapshots
MPIO/PowerPath
D@RE Encryption
XMS REST API
XtremIO X2
XMS Management
X-Brick Deploy
IB Switch
SolVe Online
iDRAC Setup
FC Zoning
iSCSI iGroups
NVRAM BBU
DAE Cabling
ESRS Remote
xcli Scripts
Snapshots
MPIO/PowerPath
D@RE Encryption
XMS REST API
Full Curriculum

4-Module D-XTR-DY-A-24 Programme

  • X2 X-Brick, IB switch, DAE/BBU/NVRAM architecture; sub-1ms latency design
  • XtremIO vs X2: NVMe SSDs, upgraded NVRAM, XDP erasure coding comparison
  • IB fabric: RDMA, subnet manager, cabling, FW; DAE expansion and hot-swap
  • XMS hardware (physical/VM); management network and iDRAC topology
  • Rack/cable: X-Brick, IB/SAS/NVMe/LAN cabling, dual-PDU power redundancy
  • SolVe Online guided procedures; offline export for air-gapped sites
  • iDRAC IP config, FW check, KVM; JBOD/DAE cable verify via XMS disk view
  • Power-on sequence: IB → DAE → Controllers; initial cluster health check
  • XMS deploy: OVF/physical; cluster create; NTP; IB switch + SM config
  • FC zoning: WWN discovery, SAN zoning; iGroups (FC/iSCSI); host registration
  • Volume create, map to iGroups; snapshot sets; post-deploy health validation
  • NVRAM BBU/SuperCap check; multipath verify; IB bandwidth metrics check
  • XMS GUI: capacity, IOPS/latency dashboards, alerts, user accounts daily ops
  • xcli and REST API for scripting; automated snapshot scheduling; monitoring
  • Snapshot/clone: CG sets, refresh, writeable snaps, reclamation operations
  • ESRS call-home setup; XCU rolling upgrade without downtime; FW lifecycle
Live Training
Live Instructor
Mon–Fri · Weekend batches
Recording
Live class recording included
30 Days
1.5 hrs/day weekday · 3 hrs weekend
Course Materials
Study notes and resources
Tech Support
Call / WhatsApp support
Working Hours
Mon–Fri · 9 AM – 6 PM
Enroll Now Download Brochure
Have Questions?

Chat with our Dell XtremIO-certified trainers instantly.

WhatsApp Us
New Batch Starting Soon — Limited Seats

Ready to Deploy Dell XtremIO X2?

Earn the D-XTR-DY-A-24 Dell Proven Professional certification and validate your hands-on skills in installing, configuring, and managing XtremIO X2 all-flash storage systems.

Enroll Now Call Us WhatsApp
Zetlan Technologies
Online — Replies in minutes
👋 Hi! Welcome to Zetlan Technologies.

Interested in Dell XtremIO Deploy D-XTR-DY-A-24? Ask us anything!
Just now
Course Details Batch Schedule Free Demo
Open WhatsApp Chat
💬 Chat with us!