ZETLAN TECHNOLOGIES
Course Categories 172+
Cloud & Infrastructure 7
Networking 8
Virtualisation 5
IT Security 10
CyberSecurity & Mgmt 14
Software Development 16
Web Dev & Database 27
Data Science & AI 14
Mobile, Testing & Games 22
Design & Creative 49
Navigation
Home Business About Us Contact Us All Courses FAQ & Help
Contact Us
+91 8680961847 +91 8680961847 (WhatsApp) info@zetlantechnologies.com
Browse by Domain
Cloud & Infrastructure 7
Networking 8
Virtualisation 5
IT Security 10
CyberSecurity & Mgmt 14
Software Development 16
Web Dev & Database 27
Data Science & AI 14
Mobile, Testing & Games 22
Design & Creative 49
2000+ Courses · 15+ Technology Domains
Microsoft Cisco AWS EC-Council View All Courses
Home  /  NetApp Certifications  /  NS0-515 E-Series SAN Specialist
Specialist Level · NetApp Certified

NS0-515
NetApp Certified Implementation Engineer — SAN Specialist, E-Series

Earn the NetApp E-Series SAN Specialist credential that validates your skills, knowledge, and capabilities in installing, configuring, and managing E-Series storage systems across various SAN environments — including FC, Ethernet, InfiniBand, and SAS — for reliable, high-performance block storage solutions.

NS0-515 E-Series SAN SANtricity Volume Groups DDP Drive Encryption Host Multipathing Fibre Channel InfiniBand iSCSI
Enroll Now
NS0-515 — E-Series SAN Specialist
NetApp Certified Implementation Engineer — SAN, E-Series
Exam CodeNS0-515
CredentialImpl. Engineer — SAN, E-Series
VendorNetApp
Exam Format60 Q / 90 min / ~75% pass
Experience6–12 months E-Series SAN
StatusActive
6
Domains
60Q
Exam
90
Minutes
NCDA
Required
Certification Overview

What This Certification Validates

The NS0-515 exam earns the NetApp Certified Implementation Engineer — SAN Specialist, E-Series credential. It validates hands-on skills in installing, configuring, and managing NetApp E-Series storage systems in SAN environments. E-Series is NetApp's dedicated, high-performance block storage platform for workloads demanding consistent, low-latency IOPS — including AI/ML, HPC, video surveillance, and enterprise applications.

Candidates should have 6–12 months of experience with E-Series storage across FC, Ethernet, InfiniBand, and SAS connectivity. The exam tests your ability to configure storage pools and volume groups, manage E-Series hardware, set up host-side multipathing, administer SANtricity System Manager and Unified Manager, implement data protection features, and troubleshoot E-Series issues.

What You Will Learn

Skills Covered

Configure E-Series storage — set up alerting and notifications, create and administer Volume Groups and Dynamic Disk Pools (DDP), configure physical and logical storage for customer requirements, and set up CHAP for iSCSI environments

Prepare documentation — review and prepare a customer site for E-Series implementation, document the pre-installation checklist, and produce post-deployment deliverables including as-built configuration records for customer handover

Manage E-Series hardware — identify hardware components in E-Series storage systems, understand Fibre Channel, Ethernet, InfiniBand, and SAS cabling, add storage expansion shelves, and configure drive encryption (FDE, FIPS)

Configure host connections — identify host connection options for E-Series systems including FC, iSCSI, SAS, and InfiniBand (iSER), and configure hosts for multipathing (MPIO, DM-Multipath, RDAC)

Administer SANtricity — perform administrative tasks with SANtricity System Manager, use SANtricity Unified Manager for multi-system management, configure security features, and use design and implementation tools for E-Series solutions

Protect and troubleshoot E-Series — use Data Assurance and media scan to protect data integrity, configure SANtricity data protection features, set up FC and Ethernet end-to-end networking, and troubleshoot E-Series and multipathing issues

Target Audience

Who Should Take This Course

Storage implementation engineers who deploy and configure NetApp E-Series storage systems for high-performance SAN workloads in enterprise data centres and HPC environments

Block storage specialists with FC, iSCSI, SAS, or InfiniBand experience who want a NetApp vendor credential validating their E-Series installation, configuration, and management skills

NetApp Certified Data Administrators (NCDA) who want to extend their ONTAP expertise with the E-Series block storage specialist credential to cover a broader range of NetApp storage platforms

NetApp partners and resellers who sell and deploy E-Series for AI/ML, HPC, video surveillance, and enterprise application workloads and need certified engineers for customer implementations

Exam Details
Exam CodeNS0-515
CredentialImpl. Engineer — SAN, E-Series
VendorNetApp
Questions60 Questions
Duration90 Minutes
Pass Score~75%
PrerequisiteNCDA Certification
DeliveryPearson VUE (Online / Centre)

Zetlan Technologies covers all 6 exam domains — Storage Configuration, Documentation, Hardware, Host Side, Management, and Protection & Troubleshooting — with expert instruction and exam-focused practice.

Course Curriculum

NS0-515 — 6 Exam Domains

Click any domain to explore all topics covered in the NS0-515 E-Series SAN Specialist exam.

1
Storage Configuration
5 Topics
Set Up Alerting and Notifications — configure email, SNMP, and syslog alerts for E-Series array events using SANtricity System Manager
Create and Administer Volume Groups or DDP — create RAID-based Volume Groups and Dynamic Disk Pools, manage associated volumes, and set volume parameters
Physical and Logical Storage Requirements — assess customer workload IOPS, capacity, and redundancy requirements to select the appropriate RAID level and pool configuration
CHAP for an iSCSI Environment — configure Challenge Handshake Authentication Protocol on E-Series for iSCSI host security and mutual authentication
DDP vs. Volume Groups — understand and select between Dynamic Disk Pool and traditional RAID Volume Group for different E-Series deployment scenarios
2
Documentation
2 Topics
Reviewing and Preparing a Site for E-Series Implementation — complete pre-installation site readiness checklists covering power, cooling, rack space, cable routes, and network connectivity
Post-Deployment Customer Deliverables — produce as-built documentation, login credentials summary, volume and host mapping records, and handover documentation after E-Series deployment
3
Hardware
4 Topics
Hardware Components in an E-Series Storage System — identify controllers, drive shelves, drive types (SSD, HDD, NVMe), host interface cards (HICs), and power/battery units
Fibre Channel, Ethernet, InfiniBand, and SAS Cabling — select and verify correct cable types, SFPs, and switch connections for each E-Series host interface protocol
Adding Storage to an E-Series System — expand capacity by adding drive shelves, replacing drives, and using SANtricity to redistribute data across the expanded pool or volume group
Drive Encryption Features — configure Full Disk Encryption (FDE) drives and FIPS-compliant drives with SANtricity Security Key Management for data-at-rest protection
4
Host Side
2 Topics
Host Connection Options for E-Series Systems — describe FC (8/16/32G), iSCSI (10/25GbE), SAS, and InfiniBand (iSER/NVMe-oF) host connectivity options and their use cases
Configure Hosts for Multipathing — install and configure NetApp SANtricity Host Utilities, set up MPIO (Windows), DM-Multipath (Linux), RDAC (Linux), and VMware NMP for E-Series multipath I/O
5
Management
4 Topics
Administrative Tasks with SANtricity System Manager — manage volumes, mappings, alerts, firmware updates, performance monitoring, and drive operations through the SANtricity web interface
Management Security Features — configure role-based access control (RBAC) in SANtricity System Manager, set up certificates, enable audit logging, and configure secure remote management
Configure and Use SANtricity Unified Manager — add and manage multiple E-Series arrays from a single Unified Manager interface, perform batch firmware upgrades and configuration tasks
Tools for E-Series Design and Implementation — use the NetApp Interoperability Matrix Tool (IMT), E-Series Configuration Tool, and SANtricity Storage Manager for solution design and deployment
6
Protection and Troubleshooting
5 Topics
Data Assurance with Media Scan — configure Data Assurance (DA) T10-PI end-to-end protection and background media scan to detect and correct silent data errors on E-Series volumes
SANtricity Data Protection Features — configure Snapshot Groups, Snapshot Volumes, Volume Copy, and Synchronous/Asynchronous Mirroring for E-Series data protection and disaster recovery
End-to-End FC and Ethernet Configuration — configure FC zoning, iSCSI VLANs, and switch-level settings for reliable E-Series connectivity and performance
Troubleshoot E-Series Systems — use SANtricity recovery guru, event log, AutoSupport, and CLI diagnostics to isolate and resolve controller, drive, networking, and performance issues
Analyze Multipathing Issues — diagnose and resolve path failover failures, load balancing anomalies, and host connectivity problems between hosts and E-Series using SANtricity and OS-level tools
FAQs

Frequently Asked Questions

What is the NS0-515 NetApp Certified Implementation Engineer — SAN Specialist, E-Series certification?
NS0-515 is a NetApp specialist-level certification that validates your ability to install, configure, and manage NetApp E-Series storage systems in SAN environments. It tests your knowledge of E-Series hardware, SANtricity configuration, host-side multipathing, data protection features, and troubleshooting for FC, iSCSI, InfiniBand, and SAS environments.
What is NetApp E-Series and when is it used?
NetApp E-Series is NetApp's dedicated, purpose-built block storage platform optimised for high-performance, consistent low-latency IOPS workloads. It is used in AI/ML and GPU-accelerated computing, HPC (high performance computing) clusters, video surveillance, gaming, financial trading, and other workloads that require guaranteed block storage performance without the overhead of a general-purpose NAS/SAN OS like ONTAP.
Is the NCDA certification required before taking NS0-515?
Yes — candidates must first achieve the NetApp Certified Data Administrator (NCDA) certification before pursuing NS0-515. The NCDA provides the foundational NetApp storage administration knowledge that the E-Series SAN Specialist exam builds upon with E-Series-specific configuration and management skills.
What SAN protocols does the NS0-515 exam cover?
NS0-515 covers all major E-Series host connectivity protocols: Fibre Channel (8/16/32G FC), iSCSI (10/25GbE), SAS, and InfiniBand (iSER). It tests your ability to cable and configure each protocol, zone FC switches, configure CHAP for iSCSI, and set up host-side multipathing for Windows (MPIO), Linux (DM-Multipath/RDAC), and VMware environments.
What does Zetlan Technologies provide for NS0-515 training?
Zetlan Technologies delivers NS0-515 training covering all 6 exam domains — Storage Configuration, Documentation, Hardware, Host Side, SANtricity Management, and Data Protection & Troubleshooting — with expert instruction, hands-on E-Series configuration walkthroughs, and exam-focused practice to ensure first-time pass success.
Get Started

Earn Your NetApp Certified Implementation Engineer — SAN Specialist, E-Series Credential — NS0-515

From E-Series storage configuration and SANtricity management to host multipathing, drive encryption, and troubleshooting — get certified with Zetlan Technologies.

Enroll Now Call Us
Zetlan Technologies
Online — Replies in minutes
👋 Hi! Welcome to Zetlan Technologies.

Interested in NS0-515 NetApp Certified Implementation Engineer SAN Specialist E-Series? Ask us anything!
Just now
Course Fee? Batch Timings? Exam Details
Open WhatsApp Chat
Your info is safe with us
💬 Chat with us!